99
5–5
Transfer Data from External Switches
In this example, positioning is executed in accordance with the number of
pulses set by external thumbwheel switches.
Configuration
C200H
PC
Word 0
IN,
16 bits
SW1 (00010)
SW2 (00000)
Others
Word 2
IN,
16 bits
Word 3
IN,
16 bits
Thumbwheel SW (leftmost digits of
positioning data)
Thumbwheel SW (rightmost digits of
positioning data)
Driver/motor
Positioning
Control
Unit #0
Data Memory
The following is the minimum data required so that an alarm will not be gen-
erated.
Initial
position
No.
0 to 19
Origin
proximity
speed 1
to F
DM 1082 2 0 0 0 Speed #1
DM 1083 0 5 0 0 Speed #2
DM 1098 0 0 0 6 Acceleration
DM 1099 0 0 0 6 Deceleration
Initial
speed
0 to F
LOW-
SPEED
JOG
1 to F
ORIGIN
SEARCH
1 to F
HIGH-
SPEED
JOG
1 to F
ORIGIN
RETURN
speed
1 to F
DM 1000 1 0 0 0
DM 1001 1 2 1 2
Data To Be Transferred
Three consecutive words are transferred for positioning action #0. The bits of
the first word, which is allocated to the Position Control Unit, are used as in-
ternal relays. The next two words are input from rotary switch connected to
Input Units allocated word 2 and word 3. Thus, when TRANSFER DATA is
executed with the beginning word designated as word 1, external data, which
has been prepared according to the data format for positioning action data,
can be used to achieve externally designated positioning actions.
Transfer Data from External Switches