Appendix D
IR Area Allocations
Function ( : leading edge; : trailing edge)
Outputs
(n = 10 x
unit no.
Word
Bit
n
n+1
n+2
n+3
n+4
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
07 to 00
15 to 08
07 to 00
14 to 08
15
15 to 00
07 to 00
15 to 08
START: At the leading edge ( ) of this bit, the Position Control Unit references
bits 01 and 07 of ch n and begins positioning.
Valid initial positioning no.: When set to 1, the initial positioning no. set in bits 07
to 00 of word n+1 is valid. When set to 0, the initial positioning no. set in bits 07 to
00 of DM word m is valid.
ORIGIN SEARCH: ( ) Searches for origin proximity signals and origin sig-
nals, and determines the origin.
ORIGIN RETURN: ( ) Returns to the origin (as long as the origin has al-
ready been determined).
RELEASE PROHIBIT: ( )
READ ERROR: ( )
CHANGE SPEED: ( ) if DIP switch pin no. 6 is ON. If pin no. 6 is OFF, then
this bit executes CHANGE SPEED when set to 1 and STOP when set to 0.
Valid speed coefficient:: When set to 1, the speed coefficient set in bits 07 to 00
of word n+2 is valid. When set to 0, the speed coefficient of the desired speed is
set at 1.0.
RESET ORIGIN: ( )
TEACH: ( ) References bits 15 to 08 of word n+1 and registers the present
position.
TRANSFER DATA: ( ) References words n+2 to n+4 and begins the trans-
fer of data.
HIGH-SPEED JOG: (0: stops, 1: operates) in the direction indicated by bit 12 of
word n.
INCH/JOG direction: (0: CW, 1: CCW)
LOW-SPEED JOG: (0: stops, 1: operates) in the direction indicated by bit 12 of
word n.
INCH: ( ) Outputs one pulse.
STOP: ( ) The Positioning cannot be restarted while this bit is set to 1.
Initial positioning action number: 00 to 19 (BCD)
TEACH positioning action number: 00 to 19 (BCD)
Speed coefficient:: 00 to 20 (BCD) in units of x 0.1
Beginning transfer number: 00 to 25 (BCD)
When set to 1, presets the present position during DATA TRANSFER.
Beginning word number for DATA TRANSFER (4 digits BCD)
PC data area for DATA TRANSFER: 00 to 04 (BCD) (00: DM, 01: I/O, 02: LR,
03: HR, 04: AR)
Number of transfers for DATA TRANSFER: 01 to 26 (BCD)