41
∆υ
= 40000/100 = 400
∆
V = 20000 x 2 = 40000
L = (
∆
V/R) = (40000/100) = 100
4
4
pps
40000
39600
39200
38800
20400
20000
19600
19200
1600
1200
800
400
4
8
12
192
196
200
204
388 396
392 400
t (Time)
ms
υ (
Speed)
400
4 ms
R = 400= 100
4
START Activation Time
The time required between START command bit recognition and the begin-
ning of pulse output is 0.1 second or less.
Only about 10 ms is required to begin execution of positioning actions with
”single” positioning actions.
External Interrupt
Response Time
The time required between CHANGE SPEED or STOP command bit recogni-
tion and the beginning of execution is at least 10 ms.
Data Transfer Time
When executing TRANSFER DATA, the busy flag (bit 12 of word n + 5) will
be ON during data transfer and processing for the following time periods:
Positioning Action Data Only (positioning actions #0 through #19)
Maximum: 0.1 s + k (scan time)
When Speed Data (Transfers #20 through #25) Are Included
Maximum: 0.2 s + k (scan time)
DM Area Allocation
Section 3–7