38
If either of these limits is reached during execution of positioning actions,
pulse output will stop, and an error code, either 5030 or 5031, will be gener-
ated.
Manual Operation
If either of these limits is reached during execution of LOW-SPEED JOG,
HIGH-SPEED JOG, or INCH, pulse output will stop, and an error code, either
5070 or 5071, will be generated.
3–7–4
Data Calculations
Speeds
Slight differences exist between speeds set in the DM area and actual
speeds. These differences do not affect positioning accuracy.
Settings between 201
and 99,990 pps
where,
INT: Nearest
integer
INT(4,000,000/set value): Divider ratio
pps:
pulses per second
Actual speed (pps) =
4,000,000
INT(4,000,000/set value)
Pulse output (actual speed)
4 MHz
Divider
A 4-MHz source clock is divided by the integral divider ratio.
Example Values
Set Value (pps)
Actual Speed (pps)
99,900
100,000.00
70,000
70,175.44
40,000
40,000.00
9,999
10,000.00
2,400
2,400.96
201
201.01