30
Data Configuration
C200H PC
IR Area
Words 100 to 109
Unit #0
Words 110 to 119
Unit #1
Words 120 to 129
Unit #2
Words 130 to 139
Unit #3
Words 140 to 149
Unit #4
Words 150 to 159
Unit #5
Words 160 to 169
Unit #6
Words 170 to 179
Unit #7
Words 180 to 189
Unit #8
Words 190 to 199
Unit #9
DM Area
Words 1000 to 1099
Unit #0
Words 1100 to 1199
Unit #1
Words 1200 to 1299
Unit #2
Words 1300 to 1399
Unit #3
Words 1400 to 1499
Unit #4
Words 1500 to 1599
Unit #5
Words 1600 to 1699
Unit #6
Words 1700 to 1799
Unit #7
Words 1800 to 1899
Unit #8
Words 1900 to 1999
Unit #9
Data is transferred
between the PC and
each Position Control
Unit each time I/O
data of the PC is re-
freshed.
Data is automatically transferred
from the PC to each Position Con-
trol Unit on power application or
when the AR area restart bit is
turned ON.
Position Control Unit
I/O refresh data areas
Words n to (n+4)
Words (n+5) to (n+9)
OUT refresh
IN refresh
Ten words are used
(n: 100 + 10 x unit no.)
Fixed data areas
Words m to m+21
Words m+22 to m+81
Words m+82 to m+97
Word m+98
Word m+99
Parameters
Position data
Speed data
Acceleration data
Deceleration data
100 words are used
(m: 1000 + 100 x unit no.)
Data Configuration and Allocation
Section 3–4