21
When the Position Control Unit is used to output voltage levels, the low level
is obtained when the output transistor turns ON, while the level goes high
when the transistor turns OFF.
Example 4:
Stepping–Motor Driver
Connection
Signal
24 V/0 V
B20
B13
B12
A12
B11
A10
B5
B2
A20
A13
A11
B4
+CW
+CCW
–CCW
E32
Stepping motor UPH599
Limit switch
(N.C. contact)
Position Control Unit
Power for
output
Origin
CCW
limit
CW limit
CW
CCW
0 V
B3
B10
+
5 VDC
+
Stepping motor driver Oriental UDX5114
Limit switch (N.O. or N.C. contact)
OMRON Photoelectric Switch
E3S-X3 CE4
(NPN output type)
–CW
Origin
proximity
Emergency
stop
24
VDC
Example 5:
Servomotor Driver
Connection
When applying the servomotor driver Z-phase output to the origin input of the
Position Control Unit, the line input/open collector conversion circuit is re-
Wiring
Section 2–2