![Omron SYSMAC C200H-NC111 Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/omron/sysmac-c200h-nc111/sysmac-c200h-nc111_operation-manual_742430092.webp)
81
4–9–5
Inch
The INCH command bit, bit 14 of word n, is set to manually inch one pulse at
a time (effective on signal’s rising edge). One pulse will be feed each time
this bit is set.
1
0
1
0
1 pulse (2.5 ms)
ON for 1 scan if the scanning time is 12 ms or longer.
(Sometimes ON for 2 scans if the scanning time is shorter than 12 ms.)
Time
INCH
word n, bit 14
Pulse output
Busy flag
word n+5, bit 12
Approx. 5ms
4–10 External Interrupt Commands
Positioning can be stopped and speeds can be changed by either the bits set
in the IR area or by external interrupt commands. The target speeds used
during CHANGE SPEED are taken in order, beginning with the lowest speed
number, from the DM area.
Acceleration
START
Time
Deceleration
Acceleration
Acceleration
Time
STOP (command executed)
Target speed #1
End position (positioning stops)
START
CHANGE SPEED (command executed)
Target speed #1
Target speed #2
Target speed #3
External Interrupt Commands
Section 4–10