80
4–9–3
High-speed Jog
The HIGH-SPEED JOG command bit (word n, bit 11) of is set to manually
feed at the designated speed (effective on signal’s rising edge). Feeding
starts when the command bit is set and continues until it is reset.
1
0
1
0
Initial speed
HIGH-SPEED JOG speed
Acceleration
Deceleration
Initial speed
Time
HIGH-SPEED JOG
word n, bit 11
Pulse output
Busy flag
word n+5, bit 12
End position (stop)
Initial position (start)
4–9–4
Low-speed Jog
The LOW-SPEED JOG command bit, bit 13 of word n, is set to manually feed
at the designated speed (effective on signal’s rising edge). Feeding starts
when the command bit is set and continues until it is reset.
1
0
1
0
Time
LOW-SPEED JOG
word n, bit 13
Pulse output
Busy flag
word 12, bit n+5
LOW-SPEED JOG speed
Initial position (start)
End position (stop)
Manual Operations
Section 4–9