66
4–4–1
Execution Examples
Example 1:
Emergency Stop
The present position is lost during an emergency stop, and positioning can-
not be started again directly after RELEASE PROHIBIT. Execute ORIGIN
SEARCH before proceeding.
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Input
6000
Time
Emergency stop signal
START
word n, bit 00
RELEASE PROHIBIT
word n, bit 04
Pulse output
Emergency stop flag
word n+5, bit 04
Error flag
word n+5, bit 05
No-origin flag
word n+5, bit 11
Busy flag
word n+5, bit 12
Alarm/error code
word n+6
ORIGIN SEARCH
word n, bit 02
1
0
0000
ORIGIN SEARCH (Begin)
Turned OFF upon completion
of ORIGIN SEARCH.
Release Prohibit
Section 4–4