6E
Emergency Stop
Torque
Set the torque limit for the following cases.
Drive prohibit deceleration with the Stop Selection
for Drive Prohibition Input (Pn66) set to 2.
Deceleration with the Stop Selection with Main Pow-
er OFF (Pn67) set to 8 or 9.
Deceleration with the Stop Selection with Servo OFF
(Pn69) set to 8 or 9.
0
%
0 to
500
---
6F
Reserved
(Do not change setting.)
---
---
---
---
70
Deviation
Counter
Overflow Level
Set the deviation counter overflow level.
100
×
256
pulses
0 to
32767
---
71
Speed
Command/
Torque
Command Input
Overflow Level
Setting
Set the overflow level for Speed Command Input (REF)
or Torque Command Input (TREF) using voltage after
offset adjustment.
0
0.1 V
0 to
100
---
72
Overload
Detection Level
Setting
Set the overload detection level.
0
%
0 to
115
---
73
Overspeed
Detection Level
Setting
Set the overspeed detection level.
0
r/min
0 to
20000
---
78
Reserved
(Do not change setting.)
---
---
---
---
79
Reserved
(Do not change setting.)
---
---
---
---
7A
Reserved
(Do not change setting.)
---
---
---
---
7B
Reserved
(Do not change setting.)
---
---
---
---
7C
Reserved
(Do not change setting.)
---
---
---
---
7D
Reserved
(Do not change setting.)
---
---
---
---
7E
Reserved
(Do not change setting.)
---
---
---
---
7F
Reserved
(Do not change setting.)
---
---
---
---
Pn
No.
Parameter name Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......