5-79
5-16 User Parameters
5
Ope
rati
ng Func
tions
Explanation of Settings
• The position command filter is the first-order lag filter for the command pulse input.
• The time constant of the position command filter can be set to one of eight values.
• The position command filter can be used for the following:
• If the command pulses change abruptly, the filter can be used to reduce the stepping movement
of the Servomotor.
• The following are examples of when the command pulses can change abruptly:
The electronic gear setting is high (10 times or higher).
The command pulse frequency is low.
Pn4C
Position Command Filter Time Constant Setting
Setting range
0 to 7
Unit
---
Default setting
0
Power OFF
→
ON
---
Setting
Explanation
0
No filter
1
Time constant: 0.2 ms
2
Time constant: 0.6 ms
3
Time constant: 1.3 ms
4
Time constant: 2.6 ms
5
Time constant: 5.3 ms
6
Time constant: 10.6 ms
7
Time constant: 21.2 ms
Position