5-83
5-16 User Parameters
5
Ope
rati
ng Func
tions
• Use these parameters to set acceleration and deceleration times for the speed command inside
the Servo Drive.
• A soft start can be set when inputting speed commands of stepping movement or when using
internally set speed.
• Do not set acceleration and deceleration times when using the Servo Drive in combination with an
external position loop. (Set both Pn58 and Pn59 to 0.)
• Refer to
on page 5-28 for more information on the soft start function.
• Use this parameter to set the pseudo-S-curve acceleration/deceleration value to add to the speed
command to enable smooth operation. This parameter is useful for applications where impact may
occur due to a large change in acceleration or deceleration when starting or stopping with linear
acceleration or deceleration.
Pn5B Torque Command/Speed Limit Selection
Pn58
Soft Start Acceleration Time
Setting range
0 to 5000
Unit 2 ms/ (1000 r/min) Default setting
0
Power OFF
→
ON
---
Pn59
Soft Start Deceleration Time
Setting range
0 to 5000
Unit 2 ms/ (1000 r/min) Default setting
0
Power OFF
→
ON
---
Pn5A
S-curve Acceleration/Deceleration Time Setting
Setting range
0 to 500
Unit
2 ms
Default setting
0
Power OFF
→
ON
---
Speed
Speed
ta
td
Internally Set Speed
Speed
1000 r/min
Speed
ta
td
ts
ts
ts
ts
1.
2.
ta: Pn58
td: Pn59
ts: Pn5A
ta
2
td
2
>
ts and
>
ts
Set as follows:
Speed
Set the linear acceleration and
deceleration times in Pn58 and
Pn59.
Set the time width for the S-curve
portion centered on the inflection
points for acceleration and
deceleration in Pn5A (unit: 2 ms).
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...