7-13
7-2 Realtime Autotuning
7
Adjustment Functions
The settings for the following parameters are automatically set and cannot be changed. (The
settings will not change even if realtime autotuning is executed.)
Note 1.
Parameters that are automatically set cannot be changed if realtime autotuning is enabled.
Note 2.
Pn31 is 10 when position control is used and the Realtime Autotuning Mode Selection
(Pn21) is set to 1 to 6. Otherwise, it is 0.
Parameter No.
Parameter name
Set value
Pn15
Feed-forward Amount
300
Pn16
Feed-forward Command Filter
50
Pn27
Instantaneous Speed Observer Setting
0
Pn30
Gain Switching Input Operating Mode Selection
1
Pn31
Control Gain Switch 1 Setting
10
Pn32
Gain Switch 1 Time
30
Pn33
Gain Switch 1 Level Setting
50
Pn34
Gain Switch 1 Hysteresis Setting
33
Pn35
Position Loop Gain Switching Time
20
Pn36
Control Gain Switch 2 Setting
0
• Unusual noise or vibration may occur until the load inertia is estimated or
the adaptive filter stabilizes after startup, immediately after the first servo
turns ON, or when the Realtime Autotuning Machine Rigidity Selection
(Pn22) is increased. This is not a problem if it disappears right away. If the
unusual noise or vibration, however, continues for three or more
reciprocating operations, take the following measures in any order you
can.
•
Write the parameters used during normal operation to the EEPROM.
•
Lower the Realtime Autotuning Machine Rigidity Selection (Pn22).
•
Manually set the notch filter.
• Once unusual noise or vibration occurs, the Inertia Ratio (Pn20) may have
changed to an extreme value. In this case, also take the measures
described above.
• Out of the results of realtime autotuning, the Inertia Ratio (Pn20) is
automatically saved to the EEPROM every 30 minutes. Realtime
autotuning will use this saved data as the default value when the power is
turned OFF and turned ON again.
• The Instantaneous Speed Observer Setting (Pn27) will automatically be
disabled (0) if realtime autotuning is enabled.
Precautions
for Correct Use
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......