5-28
5-13 Soft Start
5
Ope
rati
ng Func
tions
5-13 Soft Start
Function
• This function accelerates and decelerates the Servomotor in the set acceleration and deceleration
times.
• You can set the acceleration and deceleration independently of each other using the trapezoidal
acceleration and deceleration curve.
• The soft start processes speed command input (REF) or internally set speed control switching to
reduce impact during acceleration and deceleration.
• This function is effective for simple positioning and speed switching operations.
• Do not use this function for a position controller with an acceleration/deceleration function.
Parameters Requiring Settings
• If the soft start function is not used, set this parameter to 0 (default setting).
• The actual acceleration and deceleration time is as follows:
Parameter
No.
Parameter name
Explanation
Reference page
Pn58
Soft Start
Acceleration Time
Set the time using the following formula.
Setting = Acceleration time (setting
×
2 ms) from 0 r/min to
1,000 r/min.
Pn59
Soft Start
Deceleration Time
Set the time using the following formula.
Setting = Deceleration time (setting
×
2 ms) from 1,000
r/min to 0 r/min.
ta
td
ta = Pn58 × 2 ms/(1000 r/min)
td = Pn59 × 2 ms/(1000 r/min)
Speed command
Speed
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......