9-8
9-1 Connection Examples
9
Appe
ndix
Connection Example 8: Connecting to SYSMAC CJ1M
• Incorrect signal wiring can cause damage to Units and the Servo Drive.
• Leave unused signal lines open and do not wire them.
• Use mode 2 for origin search.
• Use the 24-VDC power supply for command pulse signals as a dedicated
power supply.
• Do not share the power supply for brakes (24 VDC) with the 24-VDC power
supply for controls.
• The diode recommended for surge absorption is the RU 2 manufactured
by Sanken Electric or the equivalent.
S
No.
37
39
35
1
5
13
2
6
X1
XB
R
T
NFB
X1
31
32
17
M
E
B
XB
DC24V
DC24V
DC24V
MC1 MC2
24 VDC
24 VDC
24 VDC
Shell
Contents
Input for the output po
w
er supply
Output COM
Origin input
signal
Positioning
completed
output
Origin
proximity input
signal
CW output
CCW output
CJ1M
3-phase 200 to 240 VAC 50/60 Hz
Noise filter
Reactor
R88-GT
@
R88M-G
@
Pulse
output 0
Servomotor
Po
w
er Cable
R88A-CAG
@
Red
White
Blue
Green/
Yello
w
Encoder Cable
R88A-CRG
@
Brake Cable
R88A-CAGA
@
B
R88A-CAGE
@
B
(Ground to
100
Ω
or less.)
Servo error display
X1
PL
ON
OFF
X
1MC
Main circuit po
w
er supply
Main circuit contactor
1MC
surge suppressor
Precautions
for Correct Use
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......