5-46
5-16 User Parameters
5
Ope
rati
ng Func
tions
5A
S-curve
Acceleration/
Deceleration
Time Setting
Set the pseudo-S-curve acceleration/deceleration value
to add to the speed command to enable smooth opera-
tion.
0
2 ms
0 to 500
---
5B
Torque
Command/
Speed Limit
Selection
Select the input for the torque command and speed
limit. For the settings and control mode, refer to the
description of the
Torque Command/Speed Limit Selec-
tion
0
---
0 to 1
---
5C
Torque
Command Scale
Set the relation between the voltage applied to the
torque command input (TREF1 or TREF2) and the Ser-
vomotor’s output torque.
30
0.1 V/
100%
10 to
100
---
5D
Torque Output
Direction Switch
Set to reverse the polarity of the Torque Command
Input (REF/TREF1 or PCL/TREF2).
0
---
0 to 1
---
0
Forward
1
Reverse
5E
No. 1 Torque
Limit
Set the limit to the Servomotor's maximum torque.
300
%
0 to 500
---
5F
No. 2 Torque
Limit
Set the limit to the Servomotor's maximum torque.
100
%
0 to 500
---
Pn
No.
Parameter name Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
O
N