5-93
5-16 User Parameters
5
Ope
rati
ng Func
tions
• If the positioning loop gain is small and the setting of this parameter is too small, a deviation
counter overflow (alarm code 24) may be detected even during normal operation.
• Deviation counter overflow (alarm code 24) will not be detected if this parameter is set to 0.
• Use this parameter to set the overflow level for Speed Command Input (REF: CN1 pin 14) or
Torque Command Input (TREF1: CN1 pin 14) using voltage after offset adjustment.
• Excessive analog input (alarm code 39) will not be detected if this parameter is set to 0.
• Use this parameter to set the overload detection level.
• The overload detection level will be 115% if this parameter is set to 0.
• This parameter should normally be set to 0. The setting should be changed only when it is
necessary to reduce the overload detection level.
• The setting of this parameter is limited to 115% of the Servomotor rating.
• Use this parameter to set the overspeed detection level.
• The overspeed detection level will be 1.2 times the maximum Servomotor rotation speed if this
parameter is set to 0.
• This parameter should normally be set to 0. The setting should be changed only when it is
necessary to reduce the overspeed detection level.
• The setting of this parameter is limited to 1.2 times the maximum Servomotor rotation speed.
• The detection margin of error for the setting is
±
3 r/min for a 7-core absolute encoder and
±
36 r/min for a 5-core incremental encoder.
Pn71
Speed Command/Torque Command Input Overflow Level Setting
Setting range
0 to 100
Unit
0.1 V
Default setting
0
Power OFF
→
ON
---
Pn72
Overload Detection Level Setting
Setting range
0 to 115
Unit
%
Default setting
0
Power OFF
→
ON
---
Pn73
Overspeed Detection Level Setting
Setting range
0 to 20000
Unit
r/min
Default setting
0
Power OFF
→
ON
---
Speed Torque
All modes
All modes
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......