5-35
5-16 User Parameters
5
Ope
rati
ng Func
tions
07
SP Selection
Select the relation between the output voltage level
and the speed.
3
---
0 to 9
---
0
Actual Servomotor speed: 6 V/47 r/min
1
Actual Servomotor speed: 6 V/188 r/min
2
Actual Servomotor speed: 6 V/750 r/min
3
Actual Servomotor speed: 6 V/3000 r/min
4
Actual Servomotor speed: 1.5 V/3000 r/min
5
Command speed: 6 V/47 r/min
6
Command speed: 6 V/188 r/min
7
Command speed: 6 V/750 r/min
8
Command speed: 6 V/3000 r/min
9
Command speed: 1.5 V/3000 r/min
08
IM Selection
Select the relation between the output voltage level
and the torque or number of pulses.
0
---
0 to 12
---
0
Torque command: 3 V/rated (100%) torque
1
Position deviation: 3 V/31 pulses
2
Position deviation: 3 V/125 pulses
3
Position deviation: 3 V/500 pulses
4
Position deviation: 3 V/2000 pulses
5
Position deviation: 3 V/8000 pulses
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Torque command: 3 V/200% torque
12
Torque command: 3 V/400% torque
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......