8-11
8-3 Troubleshooting
8
Troubleshooting
23
Encoder
communications data
error
Occurs when the power
supply is turned ON or
during operation.
•
The encoder signal
wiring is incorrect.
•
Correct the wiring.
•
Noise on the encoder
wiring causes
incorrect operation.
•
Take measures
against noise on the
encoder wiring.
•
The power supply
voltage for the
encoder has dropped
(especially when the
cable is long.)
•
Provide the required
encoder power supply
voltage (5 VDC
±
5%).
24
Deviation counter
overflow
Occurs when the Servo-
motor does not rotate
even when command
pulses are input.
•
The Servomotor
power wiring or the
encoder wiring is
incorrect.
•
Correct the wiring.
•
The Servomotor is
mechanically being
held.
•
If the Servomotor
shaft is held by
external force, release
it.
•
Release the electro-
magnetic brake.
•
Control PCB error.
•
Replace the Servo
Drive.
Occurs during
high-speed rotation.
•
The Servomotor
power wiring or the
encoder wiring is
incorrect.
•
Correct the wiring.
Occurs when a long
string of command
pulses is given.
•
Gain adjustment is
insufficient.
•
Adjust the gain.
•
The acceleration and
deceleration rapid.
•
Extend the accelera-
tion and deceleration
times.
•
The load is too large.
•
Reduce the load.
•
Select a suitable
Servomotor.
Occurs during operation.
•
The setting for the
Deviation Counter
Overflow Level (Pn70)
was exceeded.
•
Increase the setting of
Pn70.
•
Reduce the rotation
speed.
•
Lighten the load.
•
Extend the accelera-
tion and deceleration
times.
Alarm
code
Error
Status when error occurs
Cause
Countermeasure
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......