9-15
9-2 Parameter Tables
9
Appe
ndix
0D
RS-485 Baud
Rate Setting
Select the baud rate for RS-485 communications.
2
---
0 to 5
Yes
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
0E
Front Key
Protection
Setting
Front panel key operation can be limited to Monitor
Mode.
0
---
0 to 1
Yes
0
All enabled
1
Limited to Monitor Mode
0F
Reserved
(Do not change setting.)
---
---
---
---
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON