5-58
5-16 User Parameters
5
Ope
rati
ng Func
tions
Explanation of Settings
• Use this parameter to select the baud rate for RS-232 communications.
• Baud rate error: ±0.5%.
Explanation of Settings
• Use this parameter to select the baud rate for RS-485 communications.
• Baud rate error: ±0.5%.
Explanation of Settings
• Front panel key operations can be limited to Monitor Mode. This function can be used to prevent
unintended changes to parameters because of incorrect key operations.
• Even if this parameter is set to 1, parameters can be changed by using communications.
• Use communications to return this parameter to 0.
Pn0C
RS-232 Baud Rate Setting
Setting range
0 to 5
Unit
---
Default setting
2
Power OFF
→
ON
Yes
Setting
Explanation
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
Pn0D
RS-485 Baud Rate Setting
Setting range
0 to 5
Unit
---
Default setting
2
Power OFF
→
ON
Yes
Setting
Explanation
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
Pn0E
Front Key Protection Setting
Setting range
0 to 1
Unit
---
Default setting
0
Power OFF
→
ON
Yes
Setting
Explanation
0
All enabled
1
Limited to Monitor Mode
All modes
All modes
All modes
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......