5-43
5-16 User Parameters
5
Ope
rati
ng Func
tions
Position Control Parameters
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
40
Command
Pulse Input
Selection
Selects whether to use photocoupler or line-driver-only
input for the command pulse input.
When using a Servo Relay Unit cable, set to 0 (photo-
coupler input).
0
---
0 to 1
Yes
0
Photocoupler
1
Input for line driver only
41
Command
Pulse Rotation
Direction Switch
Set the Servomotor rotation direction for the command
pulse input.
0
---
0 to 1
Yes
0
The Servomotor rotates in the direction spec-
ified by the command pulse.
1
The Servomotor rotates in the opposite direc-
tion from the direction specified by the com-
mand pulse.
42
Command
Pulse Mode
Set the form of the pulse inputs sent as command to
the Servo Drive from a position controller.
1
---
0 to 3
Yes
0
90
°
phase difference (phase A/B) signal in-
puts
1
Forward pulse and reverse pulse inputs
2
90
°
phase difference (phase A/B) signal in-
puts
3
Feed pulses and forward/reverse signal input
43
Command
Pulse Prohibited
Input Setting
Enable or disable the pulse disable input (IPG).
1
---
0 to 1
---
0
Enabled
1
Disabled
44
Encoder Divider
Numerator
Setting
Set the number of encoder pulses (+A,
−
A,
−
B, +B) out-
put from the Servo Drive for each Servomotor rotation.
2500
---
1 to
32767
Yes
45
Encoder Divider
Denominator
Setting
0
---
0 to
32767
Yes
46
Encoder Output
Direction Switch
Set the phase-B logic for pulse output (
−
B, +B).
0
---
0 to 1
Yes
0
Phase-B output: Not reversed.
1
Phase-B output: Reversed.
47
Reserved
(Do not change setting.)
---
---
---
---
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......