8-13
8-3 Troubleshooting
8
Troubleshooting
40
Absolute encoder
system down error
Occurs when the power
supply is turned ON or
during operation.
•
The voltage supplied
to the absolute
encoder is low.
•
Set up the absolute
encoder.
•
Connect the battery
power supply.
41
Absolute encoder
counter overflow error Occurs during operation.
•
The multi-turn counter
of the absolute
encoder exceeds the
specified value.
•
Properly set the
Operation Switch
when Using Absolute
Encoder (Pn0B).
42
Absolute encoder
overspeed error
Occurs when the power
supply is turned ON.
•
The Servomotor
rotation speed
exceeds the specified
value when the battery
power supply is turned
ON.
•
The wiring is incorrect.
•
Lower the Servomotor
rotation speed and
supply power.
•
Check the wiring.
44
Absolute encoder
one-turn counter error
Occurs when the power
supply is turned ON.
•
The encoder is faulty.
•
Replace the Servomo-
tor.
45
Absolute encoder
multi-turn counter er-
ror
Occurs when the power
supply is turned ON.
•
The absolute encoder
detected a counter er-
ror.
•
The incremental en-
coder detected a
counter error.
•
Replace the Servomo-
tor.
46
Encoder error 1
Occurs when the power
supply is turned ON
•
The Servomotor is
faulty.
•
Replace the Servo
Drive.
•
Replace the Servomo-
tor.
47
Absolute encoder
status error
Occurs when the power
supply is turned ON.
•
The Servomotor was
moving when the
power supply was
turned ON.
•
Do not let the Servo-
motor move when the
power supply is turned
ON.
48
Encoder phase Z error Occurs during operation.
•
A phase-Z pulse from
the encoder was not
detected regularly.
•
Replace the Servomo-
tor.
49
Encoder PS signal
error
Occurs during operation.
•
A logic error was
detected in the PS
signal from the
encoder.
•
Replace the Servomo-
tor.
58
CPU error 1
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
60
CPU error 2
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
61
CPU error 3
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
62
CPU error 4
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
63
CPU error 5
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
65
Excessive analog
input 2
Occurs during operation.
•
The voltage input to
pin 16 is too high.
•
Reduce the input
voltage.
•
Change the value for
Pn71.
Alarm
code
Error
Status when error occurs
Cause
Countermeasure
ABS
ABS
ABS
ABS
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......