5-52
5-16 User Parameters
5
Ope
rati
ng Func
tions
Pn01 Default Display
Explanation of Settings
• Select the data to be displayed on the 7-segment display on the front panel after the power supply
is turned ON.
• For information on the display, refer to
Pn01
Default Display
Setting range
0 to 17
Unit
---
Default setting
1
Power OFF
→
ON
Yes
Setting
Explanation
0
Position deviation
1
Servomotor rotation speed
2
Torque output
3
Control mode
4
I/O signal status
5
Alarm code and history
6
Software version
7
Warning display
8
Regeneration load ratio
9
Overload load ratio
10
Inertia ratio
11
Total feedback pulses
12
Total command pulses
13
Reserved
14
Reserved
15
Automatic Servomotor recognition display
16
Analog input value
17
Reason for no rotation
All modes
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......