8-14
8-3 Troubleshooting
8
Troubleshooting
66
Excessive analog
input 3
Occurs during operation.
•
The voltage input to
pin 18 is too high.
•
Reduce the input
voltage.
•
Change the value for
Pn71.
73
CPU error 6
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
77
CPU error 7
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
81
CPU error 8
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
94
Encoder error 2
Occurs when the power
supply is turned ON.
•
The Servomotor is
faulty.
•
Replace the Servo
Drive.
•
Replace the Servomo-
tor.
95
Servomotor
non-conformity
Occurs when the power
supply is turned ON.
•
The Servomotor and
Servo Drive combina-
tion is incorrect.
•
Use a correct
combination.
•
The encoder wiring is
disconnected.
•
Wire the encoder.
•
Fix the locations that
are disconnected.
96
CPU error 9
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
97
CPU error 10
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
99
CPU error 11
Occurs when the power
supply is turned ON.
•
The Servo Drive is
faulty.
•
Replace the Servo
Drive.
Alarm
code
Error
Status when error occurs
Cause
Countermeasure
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......