3-14
3-1 Servo Drive Specifications
3
Specifications
*1. Do not apply a voltage that exceeds
±
10 V.
*2. Do not input a command pulse within 10 ms before and after switching.
*3. Dynamic brake operation and deviation counter clear can be selected using the Stop Selection with Servo OFF
(Pn69).
*4. Must be ON for 100
μ
s min.
*5. The deviation counter is cleared when the alarm is reset. Some alarms cannot be reset with this input.
Pin
No.
Symbol
Name
Function/Interface
Control
mode
42
BAT
Backup Battery
Input
Backup battery connector terminals when the absolute
encoder power is interrupted.
When a backup battery is connected to this terminal,
the battery case is not required.
All
43
BATGND
44
+CWLD
Reverse Pulse
(input for line driver only)
Position command pulse input when the Command
Pulse Input Selection (Pn40) is set to 1.
Line-driver input:
Maximum response frequency: 2 Mpps
Any of the following can be selected by using the Pn42
setting: reverse and forward pulses (CW/CCW), feed
pulse and direction signal (PULS/SIGN), 90
°
phase dif-
ference (phase A/B) signals (FA/FB).
Position
45
−
CWLD
46
+CCWLD
Forward Pulse
(input for line driver only)
47
−
CCWLD
ABS
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......