5-16 User Parameters
5
Ope
rati
ng Func
tions
Parameter Tables
• Some parameters are enabled by turning the power OFF and then ON again. (Those parameters
are indicated in the table.) After changing these parameters, turn OFF the power, confirm that the
power indicator has gone OFF, and then turn ON the power again.
• Do not change the parameters or settings marked “Reserved”.
Function Selection Parameters
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
00
Unit No. Setting Set the unit number.
1
---
0 to 15
Yes
01
Default Display
Set the data to display on the Parameter Unit when the
power supply is turned ON.
1
0 to 17
Yes
0
Position deviation
Pulses
1
Servomotor rotation speed
r/min
2
Torque output
%
3
Control mode
---
4
I/O signal status
---
5
Alarm code and history
---
6
Software version
---
7
Warning display
---
8
Regeneration load ratio
%
9
Overload load ratio
%
10
Inertia ratio
%
11
Total feedback pulses
Pulses
12
Total command pulses
Pulses
13
Reserved
---
14
Reserved
---
15
Automatic Servomotor recognition display
---
16
Analog input value
---
17
Reason for no rotation
---
02
Control Mode
Selection
Set the control mode to be used.
0
---
0 to 6
Yes
0
Position
1
Speed
2
Torque
3
Position/speed
4
Position/torque
5
Speed/torque
6
Reserved
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......