Control Gain
Switch 2 Setting
Select the condition for switching between gain 1 and
gain 2 in the second control mode.
The Gain Switching Input Operating Mode Selection
(Pn30) must be set to 1 (enabled).
0
---
0 to 5
---
0
Always gain 1
1
Always gain 2
2
Switching using gain switching input (GSEL)
3
Amount of change in torque command
4
Amount of change in speed command
5
Command speed
37
Gain Switch 2
Time
This parameter is enabled when Control Gain Switch
2 Setting (Pn36) is 3 to 5. Set the delay time for return-
ing from gain 2 to gain 1.
30
166
μ
s
0 to
10000
---
38
Gain Switch 2
Level Setting
This parameter is enabled when Control Gain Switch
2 Setting (Pn36) is 3 to 5. Set the judgment level for
switching between gain 1 and gain 2. The unit de-
pends on the setting of Control Gain Switch 2 Setting
(Pn36).
0
---
0 to
20000
---
39
Gain Switch 2
Hysteresis
Setting
Set the hysteresis width above and below the judg-
ment level set in the Gain Switch 2 Level Setting
(Pn38). The unit depends on the setting of the Control
Gain Switch 2 Setting (Pn36).
0
---
0 to
20000
---
3A Reserved
(Do not change setting.)
---
---
---
---
3B Reserved
(Do not change setting.)
---
---
---
---
3C Reserved
(Do not change setting.)
---
---
---
---
3D Jog Speed
Set the speed for jogging.
200
r/min
0 to
500
---
3E Reserved
(Do not change setting.)
---
---
---
---
3F Reserved
(Do not change setting.)
---
---
---
---
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......