9-22
9-2 Parameter Tables
9
Appe
ndix
48
Electronic Gear
Ratio Numerator
1
Set the pulse rate for command pulses and Servomo-
tor travel distance. If Pn48 or Pn49 is 0, the encoder
resolution is set to a numerator.
0
---
0 to
10000
---
49
Electronic Gear
Ratio Numerator
2
0
---
0 to
10000
---
4A
Electronic Gear
Ratio Numerator
Exponent
0
---
0 to 17
---
4B
Electronic Gear
Ratio
Denominator
10000
---
1 to
10000
---
4C
Position
Command Filter
Time Constant
Setting
Set the time constant for the first-order lag filter for the
command pulse input.
If the parameter is set to 0, the filter will not function.
The larger the setting, the larger the time constant.
0
---
0 to 7
---
4D
Smoothing Filter
Setting
Select the FIR filter time constant used for the com-
mand pulse input.
The higher the setting, the smoother the command
pulses.
0
---
0 to 31
Yes
4E
Deviation
Counter Reset
Condition
Setting
Set the deviation counter reset conditions.
1
---
0 to 2
---
0
Clears the deviation counter when the signal
is closed for 100
μ
s or longer.
1
Clears the deviation counter on the falling
edge of the signal (open and then closed for
100
μ
s or longer).
2
Disabled
4F
Reserved
(Do not change setting.)
---
---
---
---
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
Electronic Gear Ratio Numerator 1 (Pn48)
or
Electronic Gear Ratio Numerator 2 (Pn49)
Electronic Gear Ratio
Numerator Exponent (Pn4A)
×
2
Electronic Gear Ratio Denominator (Pn4B)
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......