5-26
5-12 Torque Limit
5
Ope
rati
ng Func
tions
5-12 Torque Limit
Function
• The torque output by the Servomotor can be limited.
• This function is effective in the following cases:
• Pressing a moving part of a machine (such as a bending machine) against a workpiece with
constant force.
• Protecting the Servomotor and mechanical system from excessive force or torque.
• The torque limit method depends on the setting of Pn03.
Parameters Requiring Settings
Pn03 = 0
During operation, the torque is limited to the torque specified with the analog voltage or the torque
set in the parameter, whichever is smaller.
• If a positive voltage between 0 and 10 V is applied to PCL (forward torque limit input), the torque
will be limited for forward operation (+3 V/100%).
• If a negative voltage between 0 and
−
10 V is applied to NCL (reverse torque limit input), the
torque will be limited for reverse operation (
−
3 V/100%).
For the parameter setting, the maximum torque is limited by Pn5E for both forward and reverse
operation.
PCL (forward torque limit input)
NCL (reverse torque limit input)
Pn5E = 300%
Pn5E = 300%
Pn5E = 100%
Pn5E = 100%
Tor
q
ue output limit
3
−
3
−
9 V
100
300[%]
9 V
Tor
q
ue command
input voltage
100
300[%]
−
3
−
9 V
9 V
3 V
Tor
q
ue output limit
Tor
q
ue command
input voltage
3
−
3
−
9 V
100
300[%]
9 V
Tor
q
ue output limit
Tor
q
ue command
input voltage
100
300[%]
3
−
3
−
9 V
100
300[%]
9 V
Tor
q
ue output limit
Tor
q
ue command
input voltage
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......