8-8
8-3 Troubleshooting
8
Troubleshooting
14
Overcurrent
Occurs when the Servo
Drive is turned ON.
•
Control PCB error
•
Replace the Servo
Drive.
•
Servomotor power line
is short-circuited or
ground-faulted
between phases.
•
Repair the short-cir-
cuited or ground-fault-
ed wire.
•
Measure the
insulation resistance
at the Servomotor
and, if there is a short-
circuit, replace the
Servomotor.
•
Miswiring between
phase U, phase V,
phase W, and ground.
•
Correct the wiring.
•
Servomotor winding is
burned out.
•
Measure the winding
resistance, and if the
winding is burned out,
replace the Servomo-
tor.
•
The relay for the
dynamic brake has
been consequently
welded.
•
Do not frequently input
the RUN Command
Input.
•
Do not operate the
system by turning the
servo ON and OFF.
•
Servomotor
non-conformity
•
Use a Servomotor that
is appropriate for use
with the Servo Drive.
•
The pulse input timing
is too fast.
•
Wait 100 ms min.
before inputting
pulses after turning
ON the RUN
Command Input
(RUN).
•
The resistor in the
Servo Drive is
abnormally
overheating.
•
Reduce the ambient
temperature of the
Servo Drive to 55
°
C or
lower.
•
If the relay doesn’t
click when the power
supply is turned ON,
replace the Servo
Drive.
•
The resistance of the
connected External
Regeneration Resistor
is less than the mini-
mum allowable value.
(For the minimum al-
lowable value, refer to
page 4-48.)
•
Connect an External
Regeneration Resistor
whose resistance is
more than the mini-
mum allowable value.
For the available com-
binations of External
Regeneration Resis-
tors and resistance
values, refer to page
4-51.
Alarm
code
Error
Status when error occurs
Cause
Countermeasure
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......