4-48
4-4 Regenerative Energy Absorption
4
System Design
Servo Drive Regenerative Energy Absorption Capacity
Amount of Internal Regeneration Absorption in Servo Drives
The OMNUC G-Series Servo Drives absorb regenerative energy internally with built-in capacitors.
If the regenerative energy is too large to be processed internally, an overvoltage error occurs and
operation cannot continue. The following table shows the regenerative energy (and amount of
regeneration) that each Servo Drive can absorb.
If these values are exceeded, take the following measures.
• Connect an External Regeneration Resistor (to improve the regeneration processing capacity).
• Reduce the operating rotation speed. (The amount of regeneration is proportional to the square of
the rotation speed.)
• Lengthen the deceleration time (to decrease the regenerative energy produced per time unit).
• Lengthen the operation cycle, i.e., the cycle time (to decrease the average regeneration power).
Note
These are the values at 100 VAC for 100-VAC models, and at 200 VAC for 200-VAC models.
Servo Drive
Regenerative
energy (J) that can
be absorbed by
internal capacitor
Internal regeneration resistance
Minimum value
of regeneration
resistance
(
Ω
)
Average amount of
regeneration that can
be absorbed (W)
Resis-
tance (
Ω
)
R88D-GTA5L
12
---
---
18
R88D-GT01L
12
---
---
18
R88D-GT02L
18
---
---
18
R88D-GT04L
27
12
50
13
R88D-GT01H
16
---
---
35
R88D-GT02H
16
---
---
35
R88D-GT04H
25
---
---
35
R88D-GT08H
43
12
100
27
R88D-GT10H
70
20
30
27
R88D-GT15H
70
20
30
18
R88D-GT20H
70
40
15
11
R88D-GT30H
70
40
15
11
R88D-GT50H
105
80
10
7
R88D-GT75H
250
---
---
4
Содержание R88D-GT series
Страница 20: ...18 Table of Contents ...
Страница 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Страница 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Страница 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Страница 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Страница 509: ......