1-456 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing link trouble
(continued)
and press the Enter key.
13
Replace faulty circuit card. Refer to the
Card Replacement procedures and
return to step 11.
14
Perform the common procedure
Placing the MP position in service
(standalone).
At the affected MP position
15
Examine the VDU display.
16
Determine if the system allocated a digital modem to the data trunk. To post
the MP position data trunk, type:
>POST T TOPSPOSDATA nnn
and press the Enter key.
where
nnn
is the position number
If TOPSPOS circuit
Do
returns to service and RES ap-
pears
step 15
fails to return to service
step 16
If MP VDU message
Do
is
Please log on
step 38
is
Link problems
encountered
step 16
is other than listed here
step 37