1-246 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing an NTFX39 bulkhead splitter unit
(continued)
37
Replace the splitter unit.
38
Secure the replacement unit with the nuts.
39
Reconnect the four cable connectors (C05 to C08) at the front of the splitter
unit. Reconnect the shrouded pin unit connections at the back of the unit.
40
Repeat step 36 for the cable connectors and shrouded pin connections on the
second IOM.
41
The next action depends on the reason for the performance of this procedure.
42
Return to the maintenance procedure that sent this procedure and continue
as directed.
At the MAP terminal
43
To return an IOM to service, type
>RTS IOC
and press Enter.
44
The next action depends on any provisioned consoles, disk drives and
magnetic tape drives.
45
To post the device port, type
>PORT port_no
and press Enter.
where
port_no
is the port identification number (0 to 17)
46
To return the device to service, type
>RTS
and press Enter.
47
Repeat steps 45 and 46 for all provisioned disk drives, consoles, and
magnetic tape drive ports.
If a maintenance procedure
Do
directed you to this procedure
step 42
did not direct you to this proce-
dure
step 43
If provisioned consoles, disk
drives and magnetic tape drive
ports
Do
are present
step 45
are not present
step 48