1-128 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing a 14-in. disk drive unit
(continued)
70
Determine if you need to add more volumes to the directory.
71
To enforce the allocation of the volumes, type
>UPDATE
and press the Enter key.
Example of a MAP response:
72
To quit the software utility for disk allocation, type
>QUIT
and press the Enter key.
73
To test the DDU controller, type
>TST
and press the Enter key.
74
To return the DDU to service, type
>RTS
and press the Enter key.
If you
Do
need to add more volumes
step 69
do not need to add more vol-
umes
step 71
If the TST command
Do
passed
step 74
failed
step 81
If the RTS command
Do
passed
step 75
WARNING: A break HX of this process may cause severe
corruption on the disk that may require it to be
reformatted.
Writing label of Volume IMAGE
Successful
Starting Initialization of Volume IMAGE
A break HX of this process may cause severe corruption on
this volume that may require reinitialization of all non
initialized volumes.
Number of Bad Blocks = 0
Successful
Update Done