Trouble locating and clearing procedures (continued) 1-495
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot RTS position
(continued)
At the TAMI
33
Examine the Position Status/Control menu.
34
Replace the new HSLI card with the original HSLI card removed in step 30.
Go to
Card Replacement Procedures, and return to step 37.
35
Perform the common procedure
Removing an MP position from service
(standalone).
36
To exit and the Position Status/Control menu and enter the TAMI main menu,
press the PF3 key. To access the Diagnostics screen, type:
>5
and press the Enter key.
Example of a TAMI response
37
To run the terminal controller diagnostics (TCD) test, type:
>POSDIAG n TCD
and press the Enter key.
where:
n
is the MP number on the TPC (0,1, 2, or 3)
Note: You can only select ManB positions.
If the VDU displays
Do
InSv
step 45
SysB
step 35
any other message
Refer to the correct locating and
clearing trouble procedure for
the indicated trouble.
Enter TPC Diagnostics command: