1-592 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MPX Token Ring LAN troubleshooting
(continued)
Data area messages have one or two lines. The number of lines depends on if
variable data is associated with the message. When two lines display, the
second line is variable data.
The three types of messages are:
•
I - Information
•
W - Warning
•
E - Error
The identification of the Data Area Message components appears below.
Soft Error
RING DIAGNOSTIC
09/21/91 13:06:29 DFIPD001I Ring diagnostic started
––––––> 10005A000133 000000A33832 000000A33832 000000A33832
09/21/91 13:06:50 DFIPD003I Printer enabled
09/21/91 13:06:56 DFIPD005I Ring test 1 started
09/21/91 13:06:56 DFIPD001E Ring error limit exceeded
––––––> 10005A0002C2 000000000 7F 10005A000311F 00000000 6A
F1 = Help 2 = Print 3 = End 4 = 5 =
F6 = Ring test 7 = Full E.R. 8 = Limited E.R. 9 = Reset Counts 10 = Pause
IDFIPD005I Ring test in progress - please wait
Data Area Messages
09/21/91 13:06:56 DFIPD001E Ring error limit exceeded
––––––> 10005A0002C2 000000000 7F 10005A000311F 00000000 6A
Sample Variable Data
Product I.D.
Message Number
Message Type
Message Description