1-324 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT
(continued)
38
Determine the result of bit error injection.
Note: In the example in step 37, the number of bit errors received appears
to the right of Rx Bit Errors.
39
Subtract the result of the C7BERT recorded in step 35 from the result
obtained in step 38.
40
To determine if any requests existed for periodic reports, type
>REPORT link_no STATUS
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
41
To clear the last report interval, type
>REPORT link_no OFF
and press Enter.
where
If the response
Do
is a display of test statistics
step 38
is other than listed here
step 66
If the difference
Do
is 6
step 33
is other than listed here
step 66
If the response
Do
is Link nn: Report interval al-
ready set at: mm times per hour
step 41
is Link nn: Automatic query re-
porting is not active
step 42
is other than listed here
step 66
Link 1: C7BERT query
Run Time : 1134 Err Free Secs: 1133
Tx Frames : 32568 Rx Sync Errs : 0
Rx Frames : 32570 Rx Bad Frames: 1
Rx Bit Errors: 6 Rx Bits : 66670792
Bit Err Rate : 1 x 10– 8