Trouble locating and clearing procedures (continued) 1-453
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
TOPS MP Operator complaint (standalone)
Clearing link trouble
(continued)
Clearing link trouble (standalone)
At your current location
1
Perform the common procedure
Removing the MP position from service
(standalone).
2
Perform the common procedure
Placing the MP position in service
(standalone).
3
Determine if the MP position returns to service.
At the affected MP position
4
Examine the VDU display.
5
Check the HSLI cable for loose connections or damage.
If the MP position
Do
returns to service and
RES
ap-
pears
step 4
fails return to service
step 5
If the message from MP VDU
Do
is
Please log on
step 38
is
Link problems
encountered
step 5
is other than listed here
step 37