Trouble locating and clearing procedures (continued) 1-85
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Replacing a 3.5 in. disk drive unit
NTFX32BA
(continued)
3
To post the port for the replaced DDU, type
>PORT port_no
and press Enter.
where
port_no
is the port number of the DDU device
Example of a IOM MAP display:
4
Record the unit number of the replaced DDU.
Note: In the example in step 3, the number of the DDU is 0.
5
Determine the state of the DDU.
Note: The state of the disk drive is under the Drive_State header on the
MAP display.
6
To determine if open files exist on the DDU, type
>ALLOC
and press Enter.
Example of a MAP display:
If the DDU is in
Do
an allocated state
step 6
other than listed here
step 38
If open files
Do
are present
step 37
Port 16 Unit
0
(SCSI)
User
system
Drive_State
Status
Ready
On_line
VOLID VOL_NAME SERIAL_NO BLOCKS ADDR TYPE R/O FILES_OPEN
0 IMAGE
2800
45000
D000 0 NO
0
1 XPMLOADS
2801
35000
D000 0 NO
0
2 RTMLOADS
2802
20000
D000 0 NO
0
.
.
.
7 SMDR
2807
5000
D000 0 NO
0
8 AMA1
2808
5000
D000 0 NO
0
9 TST
2809
50
D000 0 NO
0
10 AMA2
280A
500
D000 0 NO
0