Trouble locating and clearing procedures (continued) 1-339
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
number
is the number of reports per hour (1 to 12)
Example input:
>REPORT 1 ON 6
92
Determine if the report interval is correct.
93
To stop the C7BERT, type
>STOP link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
Note: The STOP command overrides any preset stop time without
warning
94
Give the results to the person responsible for the next level of support.
If the response
Do
is Link nn: Report interval set at:
is nn times per hour
step 92
is other than listed here
step 109
If the interval
Do
is correct
step 82
is wrong
step 90
If the response
Do
is Link 1: C7BERT stopped
is with a display of test statistics
step 94
is other than listed here
step 109
If
Do
the link stops on an NT9X77AA or
NT9X78BA/CA/DA/DB card, and you just ran a link
fault sectionalization. If instructions required you to
return the link to service
step 98