Trouble locating and clearing procedures (continued) 1-357
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
43
To determine if a stop time has been set, type
>SETSTOP link_no STATUS
and press the Enter key.
where
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
44
To clear the stop time, type
>SETSTOP link_no CLEAR
and press the Enter key.
where
link_no
is the number of the link on which the HSL C7BERT is running
45
To set the new stop time, type
>SETSTOP link_no SET day hours minutes
and press the Enter key.
where
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
day
is the day on which you want the test to stop automatically (MON, TUE,
WED, THU, FRI, SAT, or SUN)
you want to stop the test auto-
matically at a pre-set time
step 43
you want to inject bit errors
step 48
If the response is
Do
Link nn: Stop time set at:
time
step 44
Link nn: No stop time has been
set
step 45
anything else
step 78
If the response is
Do
Stop time cleared
step 45
anything else
step 78
If
Do