1-496 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MP Operator complaint (standalone)
Clearing position failure - cannot RTS position
(continued)
Example of a TAMI response
38
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
39
Replace the base controller. Go to
Card Replacement Procedures and return
step 37.
40
Replace the new base controller with the original base controller replaced in
step 39. Go to
Card Replacement Procedures and return to the next step.
41
To exit the Diagnostics screen, type:
>QUIT
and press the Enter key.
42
Perform the common procedure
Placing MP positions in service
(standalone).
At the TAMI
43
Examine the Position Status/Control menu.
If TCD diagnostics test
Do
passes
step 41
fails
step 38
fails with base controller re-
placed
step 40
If the VDU displays
Do
InSv
step 45
SysB
step 44
Performing ROM position Component Diagnostic...
Performing CPU position Component Diagnostic...
Performing Exceptions position Component Diagnostic...
Performing RAM position Component Diagnostic...
Performing HSLI Port position Component Diagnostic...
Performing UART position Component Diagnostic...
Performing Keyboard position Component Diagnostic...
Performing Telephony position Component Diagnostic...