Trouble locating and clearing procedures (continued) 1-355
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT for high-speed links
(continued)
Note: The STOP command overrides any preset stop time without
warning.
37
To remove the far-end DS-1 ESF loopback already applied, type
>CARLOOP STOP link_no
and press the Enter key.
where
link_no
is the number of the link you entered in step 34
38
Contact personnel at the intermediate point and request a loopback.
39
To start the HSL C7BERT, type
>START link_no
and press the Enter key.
where
link_no
is the number of the link you want to test (0 to 15)
40
To display the test results of the HSL C7BERT, type
>QUERY link_no PR
and press the Enter key.
where
If the response is
Do
Link 1: C7BERT stopped
step 34
anything else
step 78
If the response is
Do
CARLoop stop n
Link n: DS-1 ESF OFF complete
step 34
anything else
step 78
If the response is
Do
Link n: C7BERT started
step 40
Link n:Failed - Link state is in-
valid for HSL C7BERT
Link must be SysB/DAct or
SysB/CAR
step 16
anything else
step 78