Trouble locating and clearing procedures (continued) 1-325
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
link_no
is the number of the link that the C7BERT runs on
MAP response:
42
To set the number of reports per hour, type
>REPORT link_no ON number
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
number
is the number of reports per hour (1 to 12)
Example input:
>REPORT 1 ON 6
43
Determine if the report interval is correct.
44
Stop the C7BERT that exists, type
>STOP link_no
and press Enter.
where
link_no
is the number of the link (0 to 15) that the C7BERT runs on
Note: The STOP command overrides any preset stop time without
warning.
If the response
Do
is Link nn: Report interval set
at:is nn times per hour
step 43
is other than listed here
step 66
If the interval
Do
is correct
step 33
is wrong
step 41
If the response
Do
is Link 1: C7BERT stopped
is with a display of test statistics
step 45
is other than listed here
step 66
Link nn: Automatic query reporting has been terminated