1-598 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
TOPS MPX Token Ring LAN troubleshooting
(continued)
09/21/91 13:06:56 DFIPD040E Ring diagnostic initialization failed
––––––> 0010 10005A00133 000000A33832 000000A33832 000000A33832
The
Address of
this
Adapter
The Code
Level of
this
Adapter
Adapter
Support
Interface
Code Level
Ring
Diagnostic
Code Level
Reason
Code
(Sheet 1 of 2)
Reason
Code
Reason
Action
0002
Initialize command fails.
Refer to Action #1 after this
table.
0003
Open command fails.
Refer to Action #1 after this
table.
0007
Status command fails.
Refer to Action #1 after this
table.
0008
Adapter already in use.
Use optional parameter /l to
invoke the Ring diagnostic.
000A
Parameters were not passed to
the Ring Diagnostic.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
000E
Wrong optional parameter.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
000F
Printer initialization fails.
Remedy the problem with the
printer.
0010
Help initialization fails.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
0015
Error reporter fails.
Use a different System Diskette.
A problem with the Ring
Diagnostic is present.
0018
The wrong level of DOS is used.
Make sure you use the DOS
version 4.0 or higher.