Trouble locating and clearing procedures (continued) 1-313
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Running a C7BERT
(continued)
Running a C7BERT
At the MAP terminal
1
Contact the next level of support to obtain the following information:
•
how the test will stop (manually or automatically), and
•
if periodic reports are required, and if so, how many times each hour (1
to 12)
2
If you perform a remote loopback, inform a person at the far-end office that
•
you will busy and deactivate the link, and
•
the person must busy and deactivate the link at their end
3
To access the C7LKSET level of the MAP display, type
>MAPCI;MTC;CCS;CCS7;C7LKSET
and press Enter.
Example of a MAP response:
4
To post the linkset that includes the link you want to test, type
>POST C linkset_name
and press Enter.
where
linkset_name
is the name of the linkset (as defined in table C7LKSET)
ATTENTION
To run link fault sectionalization (LFS) the SOC option TEL0007 must
have the RTU set to “Y" and the state set to “on".
ATTENTION
If link fault sectionalization (LFS) is activated, an anomaly in the
NT9X78BA and NT9X78CA cards can cause latch past to occur. When
the last DS0DP is a BA or CA paddle board, LFS may latch past the last
DS0DP link.For example, if the fifth and last device in a link is a BA or
CA card, LFS may latch the sixth or seventh DS0DP.Before running this
procedure, check the number and type of devices on a link. This
information helps reduce the link diagnosis time.
Traf Sync
Link
LK Stat Stat Resource Stat Physical Access Stat
Action