1-648 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
VSLE session defaults to audio SLE
(continued)
9
Perform PM maintenance on the PM currently posted and return to this point.
10
Go to step 23.
11
Use the following information to determine the next step in this procedure.
12
See
Card Replacement Procedures and return to this point.
13
To load the CMR card in the PM, type
>LOADPM UNIT unit_no CC CMR
and press Enter.
where
unit_no
is the number of the PM (0 or 1)
Note: Use the LOADPM command to load the CMR card separate from
the PM.
If CMR card
Do
is on the card list
step 11
is not on the card list
step 9
If
Do
a first-time replacement of the
CMR card
step 12
replaced CMR card already
step 22
If response
Do
is the loading completes correctly
step 17
is CMR FAILED TO LOAD. TASK ABORTED
WHILE LOADING CMR
step 14
is CMR FILE CMR33A15 NOT FOUND ON DE-
VICE
INDICATED
IN
TABLE
PMLOADS
Note:CMR33A15 is the CMR load name
step 14
RTS Failed, TESTALL
Diagnostic TESTALL failed.
Fail message received from PM
Replace the Cards in the Card List
and applicable Paddleboards (i.e. 6X12) :
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 01 D02 LGE 00 18 LGC : 000 13 6X78