1-218 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Replacing a line card
(continued)
Replacing a line card
At the MAP terminal
1
To display the location and product engineering code (PEC) for the line card,
type
>MAPCI;MTC;PM;POST LCME <LCME_NO>;QUERYPM
and press the Enter key.
Example of a MAP display:
CI:
>MAPCI NODISP; MTC; PM; POST LCME36 0; QUERYPM
MAPCI:
MTC:
PM:
POST:
PM TYPE: LCME Int. No.: 10 Status index: 5 Node_No: 177
LCME HOST 36 0 Memory Size-Unit 0: 256K, Unit 1: 256K
Loadnames: LCMINV - LCME81BA, Unit0: LCME81BA,
Unit1: LCME81BA
LCM REX is ON; PASSED on TUE. 1997/10/28 at 01:30:05
Node Status: {OK, FALSE}
Unit 0 Status: {OK, FALSE} /RG: 1
Unit 1 Status: {OK, FALSE} /RG: 1
Ring Generator Status:
RG 0 Status: {OK} Preferred
RG 1 Status: {OK} Standby
RG in Overload : NO
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 03 CC06 LCEI 36 04 LCME 36 0 BX30AB
Services : ISDN Equipped
Note: In this example, the location of the line card is
Site
in the HOST office
Flr
on the 3rd floor
RPos
in row C that contains the line equipment bay, 01,
WARNING
Possible equipment damage
Proceed only when a maintenance procedure directs you to
this procedure. Separate use of this procedure can cause
equipment damage or loss of service.