Trouble locating and clearing procedures (continued) 1-247
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Replacing an NTFX39 bulkhead splitter unit
(end)
48
The next action depends on any provisioned MPC ports.
49
To post the MPC port, type
>PORT port_no
and press Enter.
where
port_no
is the port identification number (0 to 17)
50
To return the MPC to service, type
>RTS
and press Enter.
Example of MAP response:
51
Check the status of MPC components
52
Repeat steps 49 to 51 for each provisioned port on the shelf.
53
Notify users that MPC service is available.
54
Repeat steps 43 to 53 to put the second IOM back into service.
55
Consult an office person to determine why the component is off-line.
Continue as directed by the office person.
56
You cannot busy the controller if files are open. The result can be the loss of
billing data. For additional help, contact the person responsible for the next
level of support.
57
For additional help, contact the person responsible for the next level of
support.
58
The procedure is complete.
If provisioned MPC ports
Do
are present
step 49
are not present
step 50
If
Do
the system status is Ready, the
port status is COMACT, and the
link status is enabled for each
provisioned link.
step 52
other than listed here
step 57
REQUEST PASSED FOR UNIT
REQUEST PASSED FOR LINKS